NucTrap® Purification Push Columns

Outline

NucTrap purification push columns can be used to purify radiolabeled DNA- and RNA-probes ranging in size between 17 bp and 50,000 bp.

Supplies & Equipment:

Reagents:

Procedure:

  1. Prewet column (pipet 70 µl 1 x STE on top of column, push through with air using syringe)
  2. Load sample (within 5 - 10 minutes after prewetting), push through slowly as before
  3. Wash (pipet 70 µl 1 x STE on top of column, push through as before)
  4. Elute with 70 µl dH2O, or 10 mM Tris, or TE-Buffer 

Time Required:

ca. 10 minutes

Return to: Home - LabLinks - GH-PRL-PL